제품소개

화인인터코리아는 최상의 솔루션을 제공하는 혁신적인 회사가 될 것입니다.

인디게이터

제목 FS-8000A





4Kinds of Accumulated Weighing Control





FS-8000A Weighing Indicator is particularly suited for weight and measures approved
applications such as a Packer, Limit, 4Kinds of Materials Mixing, a precise Feed Weighing
Accumulated Weighing, Weight Checking through 1st, 2nd, 3rd, 4th. 4Step Control Relay.

FS-8000A also is available in a robust Aluminium housing for front panel mounting.
Particularly optimum use for interference suppression and long-term stability in harshest
environment.





Features

● Easy and Comfortable Calibration Operations (Zero Adjust Range: -4 mV ~ 42.0 mV)
● High Non-Linearty Rate( 0.005% of Full Scale.)
● 4Step Control Relay(1st, 2Nd, 3rd, 4th)
● Standard RS-232C/Current Loop Interface Built In for PC,PLC, External Equipment.
● Max. Display 7 Segment. 7Digit Blue Color Display, Blue Color Display
● Auto Free Fall Compensation
● Bulk, Drib, Fall, Free Fall, Finish, Empty/Zero 6pcs Relay Built In.
● Analog Out(Option) Zero / Span Adjustable by Function Key.









Specification



1. Analog Input & A/D Conversion Section

 Input Sensitivity  0.2 μ V/D
 Zero Adjust Range  -4 mV ~ 42.0 mV
 Load cell Supply Voltage  DC 10V( ± 5V)
 Max. loadcell Input Voltage  32 mV
 Temperature Coefficient  ± 20 ppm / °C
 Input Noise  ± 0.5 μv P.P
 Input Impedance  More than 10 ΜΩ
 A/D Conversion  130,000 Count
 Non-Linearty Range  0.005% of Full Scale
 Conversion Method  Dual - Slop







2. Digital Section


 Max. Display                                      “1000000”
 A Digit  x1, x2, x5, x10, x20, x50
 Display  7 Segment, 7Digit Highly Bright Fluorescent Tube
 Character Size  10mm Height
 Keypad  Numeral Keypad and Function Key(0~9),CLR,SET,PRINT
 Data Back-Up  Permanent Record









3. General Section



 Power Voltage  VAC 110 / 220V(± 10%), 50/60Hz
 Indicator Weight  Net 3.3Kg, Packing 3.8Kg
 Temperature  -10 °C ~ 40°C
 Moisture  Less than 85% RH
 Dimension  193.6mm x 98mm x 160mm







4. Option Section



 Basic Standard 1  Serial Interface : RS-232C
 Option 2  Current Loop
 Option 3  Parallel Interface : BCD OUT Weight( Positive, Negative Logic)
 Option 4  Serial Interface : RS-422, RS-485
 Option 5  Analog Output : 0~10V or 10V ~ 0V
 Option 6  Analog Output : 4~20 mA or 20 ~ 4 mA
 Option 7  Printer Interface : Centronics Parallel
 Option 10  Parallel Interface : BCD In PART









Cutting size








Applications




TOP